Charging
Cycle Applications: Limit initial current
to 7200mA. Charge until battery voltage (under charge) reaches 7.20 to
7.35 volts at 68º F (20º C). Hold at 7.20 to 7.35 volts until current
drops to approximately 360mA. Battery is fully charged under these
conditions, and charger should either be disconnected or switched to
"float" voltage.
"Float" or "Stand-by Service": Hold battery
across constant voltage source of 6.75 to 6.90 volts continuously. When
held at this voltage, the battery will seek its own current level and
maintain itself in a fully charged condition. |